Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Proc IEEE Sens ; 20222022.
Article in English | MEDLINE | ID: covidwho-2171071

ABSTRACT

Recent advances in remote-photoplethysmography (rPPG) have enabled the measurement of heart rate (HR), oxygen saturation (SpO2), and blood pressure (BP) in a fully contactless manner. These techniques are increasingly applied clinically given a desire to minimize exposure to individuals with infectious symptoms. However, accurate rPPG estimation often leads to heavy loading in computation that either limits its real-time capacity or results in a costly setup. Additionally, acquiring rPPG while maintaining protective distance would require high resolution cameras to ensure adequate pixels coverage for the region of interest, increasing computational burden. Here, we propose a cost-effective platform capable of the real-time, continuous, multi-subject monitoring while maintaining social distancing. The platform is composed of a centralized computing unit and multiple low-cost wireless cameras. We demonstrate that the central computing unit is able to simultaneously handle continuous rPPG monitoring of five subjects with social distancing without compromising the frame rate and rPPG accuracy.

2.
BMJ Open ; 12(12): e062707, 2022 12 09.
Article in English | MEDLINE | ID: covidwho-2161854

ABSTRACT

OBJECTIVES: Mask adherence continues to be a critical public health measure to prevent transmission of aerosol pathogens, such as SARS-CoV-2. We aimed to develop and deploy a computer vision algorithm to provide real-time feedback of mask wearing among staff in a hospital. DESIGN: Single-site, observational cohort study. SETTING: An urban, academic hospital in Boston, Massachusetts, USA. PARTICIPANTS: We enrolled adult hospital staff entering the hospital at a key ingress point. INTERVENTIONS: Consenting participants entering the hospital were invited to experience the computer vision mask detection system. Key aspects of the detection algorithm and feedback were described to participants, who then completed a quantitative assessment to understand their perceptions and acceptance of interacting with the system to detect their mask adherence. OUTCOME MEASURES: Primary outcomes were willingness to interact with the mask system, and the degree of comfort participants felt in interacting with a public facing computer vision mask algorithm. RESULTS: One hundred and eleven participants with mean age 40 (SD15.5) were enrolled in the study. Males (47.7%) and females (52.3%) were equally represented, and the majority identified as white (N=54, 49%). Most participants (N=97, 87.3%) reported acceptance of the system and most participants (N=84, 75.7%) were accepting of deployment of the system to reinforce mask adherence in public places. One third of participants (N=36) felt that a public facing computer vision system would be an intrusion into personal privacy.Public-facing computer vision software to detect and provide feedback around mask adherence may be acceptable in the hospital setting. Similar systems may be considered for deployment in locations where mask adherence is important.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Male , Female , Humans , COVID-19/prevention & control , Masks , Personnel, Hospital , Computers , Observational Studies as Topic
3.
Cyborg Bionic Syst ; 20222022.
Article in English | MEDLINE | ID: covidwho-1848132

ABSTRACT

The COVID-19 pandemic has accelerated methods to facilitate contactless evaluation of patients in hospital settings. By minimizing in-person contact with individuals who may have COVID-19, healthcare workers can prevent disease transmission and conserve personal protective equipment. Obtaining vital signs is a ubiquitous task that is commonly done in person by healthcare workers. To eliminate the need for in-person contact for vital sign measurement in the hospital setting, we developed Dr. Spot, a mobile quadruped robotic system. The system includes IR and RGB cameras for vital sign monitoring and a tablet computer for face-to-face medical interviewing. Dr. Spot is teleoperated by trained clinical staff to simultaneously measure the skin temperature, respiratory rate, and heart rate while maintaining social distancing from patients and without removing their mask. To enable accurate, contactless measurements on a mobile system without a static black body as reference, we propose novel methods for skin temperature compensation and respiratory rate measurement at various distances between the subject and the cameras, up to 5 m. Without compensation, the skin temperature MAE is 1.3°C. Using the proposed compensation method, the skin temperature MAE is reduced to 0.3°C. The respiratory rate method can provide continuous monitoring with a MAE of 1.6 BPM in 30 s or rapid screening with a MAE of 2.1 BPM in 10 s. For the heart rate estimation, our system is able to achieve a MAE less than 8 BPM in 10 s measured in arbitrary indoor light conditions at any distance below 2 m.

4.
JAMA Netw Open ; 4(3): e210667, 2021 03 01.
Article in English | MEDLINE | ID: covidwho-1116912

ABSTRACT

Importance: Before the widespread implementation of robotic systems to provide patient care during the COVID-19 pandemic occurs, it is important to understand the acceptability of these systems among patients and the economic consequences associated with the adoption of robotics in health care settings. Objective: To assess the acceptability and feasibility of using a mobile robotic system to facilitate health care tasks. Design, Setting, and Participants: This study included 2 components: a national survey to examine the acceptability of using robotic systems to perform health care tasks in a hospital setting and a single-site cohort study of patient experiences and satisfaction with the use of a mobile robotic system to facilitate triage and telehealth tasks in the emergency department (ED). The national survey comprised individuals living in the US who participated in a sampling-based survey via an online analytic platform. Participants completed the national survey between August 18 and August 21, 2020. The single-site cohort study included patients living in the US who presented to the ED of a large urban academic hospital providing quaternary care in Boston, Massachusetts between April and August 2020. All data were analyzed from August to October 2020. Exposures: Participants in the national survey completed an online survey to measure the acceptability of using a mobile robotic system to perform health care tasks (facilitating telehealth interviews, acquiring vital signs, obtaining nasal or oral swabs, placing an intravenous catheter, performing phlebotomy, and turning a patient in bed) in a hospital setting in the contexts of general interaction and interaction during the COVID-19 pandemic. Patients in the cohort study were exposed to a mobile robotic system, which was controlled by an ED clinician and used to facilitate a triage interview. After exposure, patients completed an assessment to measure their satisfaction with the robotic system. Main Outcomes and Measures: Acceptability of the use of a mobile robotic system to facilitate health care tasks in a hospital setting (national survey) and feasibility and patient satisfaction regarding the use of a mobile robotic system in the ED (cohort study). Results: For the national survey, 1154 participants completed all acceptability questions, representing a participation rate of 35%. After sample matching, a nationally representative sample of 1000 participants (mean [SD] age, 48.7 [17.0] years; 535 women [53.5%]) was included in the analysis. With regard to the usefulness of a robotic system to perform specific health care tasks, the response of "somewhat useful" was selected by 373 participants (37.3%) for facilitating telehealth interviews, 350 participants (35.0%) for acquiring vital signs, 307 participants (30.7%) for obtaining nasal or oral swabs, 228 participants (22.8%) for placing an intravenous catheter, 249 participants (24.9%) for performing phlebotomy, and 371 participants (37.1%) for turning a patient in bed. The response of "extremely useful" was selected by 287 participants (28.7%) for facilitating telehealth interviews, 413 participants (41.3%) for acquiring vital signs, 192 participants (19.2%) for obtaining nasal or oral swabs, 159 participants (15.9%) for placing an intravenous catheter, 167 participants (16.7%) for performing phlebotomy, and 371 participants (37.1%) for turning a patient in bed. In the context of the COVID-19 pandemic, the median number of individuals who perceived the application of robotic systems to be acceptable for completing telehealth interviews, obtaining nasal and oral swabs, placing an intravenous catheter, and performing phlebotomy increased. For the ED cohort study, 51 individuals were invited to participate, and 41 participants (80.4%) enrolled. One participant was unable to complete the study procedures because of a signaling malfunction in the robotic system. Forty patients (mean [SD] age, 45.8 [2.7] years; 29 women [72.5%]) completed the mobile robotic system-facilitated triage interview, and 37 patients (92.5%) reported that the interaction was satisfactory. A total of 33 participants (82.5%) reported that their experience of receiving an interview facilitated by a mobile robotic system was as satisfactory as receiving an in-person interview from a clinician. Conclusions and Relevance: In this study, a mobile robotic system was perceived to be acceptable for use in a broad set of health care tasks among survey respondents across the US. The use of a mobile robotic system enabled the facilitation of contactless triage interviews of patients in the ED and was considered acceptable among participants. Most patients in the ED rated the quality of mobile robotic system-facilitated interaction to be equivalent to in-person interaction with a clinician.


Subject(s)
Delivery of Health Care/methods , Emergency Service, Hospital , Hospitals , Patient Care/methods , Patient Satisfaction , Robotics/methods , Triage , Adult , Aged , Boston , COVID-19 , Catheterization , Feasibility Studies , Female , Humans , Male , Middle Aged , Pandemics , Phlebotomy , Physical Examination , Surveys and Questionnaires , Telemedicine
5.
ACS Pharmacol Transl Sci ; 3(6): 1076-1082, 2020 Dec 11.
Article in English | MEDLINE | ID: covidwho-1065796

ABSTRACT

N95 filtering facepiece respirators (FFR) and surgical masks are essential in reducing airborne disease transmission, particularly during the COVID-19 pandemic. However, currently available FFR's and masks have major limitations, including masking facial features, waste, and integrity after decontamination. In a multi-institutional trial, we evaluated a transparent, elastomeric, adaptable, long-lasting (TEAL) respirator to evaluate success of qualitative fit test with user experience and biometric evaluation of temperature, respiratory rate, and fit of respirator using a novel sensor. There was a 100% successful fit test among participants, with feedback demonstrating excellent or good fit (90% of participants), breathability (77.5%), and filter exchange (95%). Biometric testing demonstrated significant differences between exhalation and inhalation pressures among a poorly fitting respirator, well-fitting respirator, and the occlusion of one filter of the respirator. We have designed and evaluated a transparent elastomeric respirator and a novel biometric feedback system that could be implemented in the hospital setting.

6.
BMJ Open ; 10(7): e039120, 2020 07 07.
Article in English | MEDLINE | ID: covidwho-639452

ABSTRACT

OBJECTIVE: To develop and test a new reusable, sterilisable N95 filtering facepiece respirator (FFR)-comparable face mask, known as the Injection Molded Autoclavable, Scalable, Conformable (iMASC) system, given the dire need for personal protective equipment within healthcare settings during the COVID-19 pandemic. DESIGN: Single-arm feasibility study. SETTING: Emergency department and outpatient oncology clinic. PARTICIPANTS: Healthcare workers who have previously undergone N95 fit testing. INTERVENTIONS: Fit testing of new iMASC system. PRIMARY AND SECONDARY OUTCOME MEASURES: Primary outcome is success of fit testing using an Occupational Safety and Health Administration (OSHA)-approved testing method, and secondary outcomes are user experience with fit, breathability and filter replacement. RESULTS: Twenty-four subjects were recruited to undergo fit testing, and the average age of subjects was 41 years (range of 21-65 years) with an average body mass index of 26.5 kg/m2. The breakdown of participants by profession was 46% nurses (n=11), 21% attending physicians (n=5), 21% resident physicians (n=5) and 12% technicians (n=3). Of these participants, four did not perform the fit testing due to the inability to detect saccharin solution on premask placement sensitivity test, lack of time and inability to place mask over hair. All participants (n=20) who performed the fit test were successfully fitted for the iMASC system using an OSHA-approved testing method. User experience with the iMASC system, as evaluated using a Likert scale with a score of 1 indicating excellent and a score of 5 indicating very poor, demonstrated an average fit score of 1.75, breathability of 1.6, and ease of replacing the filter on the mask was scored on average as 2.05. CONCLUSIONS: The iMASC system was shown to successfully fit multiple different face sizes and shapes using an OSHA-approved testing method. These data support further certification testing needed for use in the healthcare setting.


Subject(s)
Coronavirus Infections/prevention & control , Equipment Design , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Respiratory Protective Devices , Silicone Elastomers , Adult , Aged , Allied Health Personnel , Betacoronavirus , COVID-19 , Coronavirus Infections/transmission , Equipment Reuse , Feasibility Studies , Female , Humans , Male , Middle Aged , Nurses , Physicians , Pneumonia, Viral/transmission , Prospective Studies , SARS-CoV-2 , Sterilization , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL